Photos shown for illustration; shade and shape may differ slightly.
Cartek PDP-08 8-Channel Electrical Distribution Panel
The Cartek PDP-08 8-channel electrical distribution panel centralises the power supply and control of a race car's electrical equipment. It combines a power distribution module and a button panel in one housing and replaces the fuses, relays and switches of the circuits it controls.
Each channel has electronic protection against overcurrent and short circuit. The function and current threshold are configured directly from the panel buttons, without a computer. The equipment is then controlled from the front panel, remote switches or the engine control unit inputs.
Specifications
| Model | Cartek PDP-08 |
| Power outputs | 8 configurable channels |
| Total continuous current available | 80 A |
| Current thresholds per channel | 5, 10 or 15 A |
| Channels paired | settings of 20, 25 or 30 A |
| Engine control unit inputs | 8 |
| Control inputs or outputs | 8 |
| Dedicated input for the Cartek XR electronic isolator | 1 |
| Windscreen wiper | dedicated function, with rest position input |
| Backlight | two brightness levels |
| Front panel size | 145 x 140 mm |
| Weight | 450 g |
| Operating temperature | -10 °C to +85 °C |
| Main supply | battery positive, via M6 stud |
| Compatible harness connector | AMPSEAL black 776164-1, not included |
| Dust protection | front and rear gaskets |
| Brand | Cartek |
| Code | CK-PDP-08 |
Configurable functions
- Momentary control, for example for the starter solenoid.
- On/off with memory: keeps the channel state after a power loss.
- On/off without memory: returns to off after a power loss.
- Timer control: particularly suitable for a heated windscreen.
- Flashing: for controlling indicators.
- Toggle: to choose between low and high beam.
- Momentary ground control: for an ECU input, for example selecting a map.
Control and diagnostics
Status indicators show each channel: off when the output is deactivated, on when it is active, with a warning light on overcurrent or short circuit. External inputs allow remote controls and let the engine control unit operate certain equipment, for example the fuel pump.
Included
- Cartek PDP-08 distribution panel.
- Two sets of labels: one multicolour and one black and white.
Wiring and mounting
- The harness connector and contacts are not included and are ordered separately.
- Size the wiring from the equipment being powered, without exceeding the total limit of 80 A continuous.
- Settings of 20-30 A require combining two channels, following the Cartek instructions.
- This part is intended for competition. Using it on public roads may be prohibited if it alters the characteristics stated in the vehicle's type-approval certificate.